Index des codes défaut · medium
P0032
HO2 Sensor heater control circuit high current – bank 1, upstream (1/1)
HO2 Sensor heater control circuit high current – bank 1, upstream (1/1)
Documented for: 2.0L gasoline; 2.5L/3.0L gasoline · System(s): EMS EOBD, EMS OBD II · Factory MIL flag: 2 · Default action: ECM Default: –Bank 1 closed loop fuel metering and adaptive fuel metering inhibited –Canister purge inhibited –Bank 1 upstream HO2S heater control circuit switched off
Common causes
- HO2 Sensor 1/1 heater control circuit: short circuit to ground HO2 Sensor 1/1 heater ground circuit(s) fault (EN65-075, EN65-102) HO2 Sensor 1/1 heater failure
- HO2 Sensor 1/1 heater control circuit: short circuit to ground HO2 Sensor 1/1 heater ground circuit(s) fault (EN16-029, EN16-030) HO2 Sensor 1/1 heater failure
Quick checks
- Confirm freeze-frame and conditions when the code set
- Inspect connectors, grounds, and harness for the circuit named in the code
- Compare live sensor values vs expected (unplugged/biased sensors are common)