X‑TYPE Baza wiedzy

Indeks kodów błędów · medium

P0031

HO2 Sensor heater control circuit low current – bank 1, upstream (1/1)

HO2 Sensor heater control circuit low current – bank 1, upstream (1/1)

Documented for: 2.0L gasoline; 2.5L/3.0L gasoline · System(s): EMS EOBD, EMS OBD II · Factory MIL flag: 2 · Default action: ECM Default: –Bank 1 closed loop fuel metering and adaptive fuel metering inhibited –Canister purge inhibited –Bank 1 upstream HO2S heater control circuit switched off

Common causes

  • HO2 Sensor 1/1 heater power supply circuit: open circuit HO2 Sensor 1/1 heater control circuit: open circuit, high resistance HO2 Sensor 1/1 heater ground circuit(s) fault (EN65-075, EN65-102) HO2 Sensor 1/1 heater failure
  • HO2 Sensor 1/1 heater power supply circuit: open circuit HO2 Sensor 1/1 heater control circuit: open circuit, high resistance HO2 Sensor 1/1 heater ground circuit(s) fault (EN16-029, EN16-030) HO2 Sensor 1/1 heater failure

Quick checks

  • Confirm freeze-frame and conditions when the code set
  • Inspect connectors, grounds, and harness for the circuit named in the code
  • Compare live sensor values vs expected (unplugged/biased sensors are common)

Indeks kodów błędów →