X‑TYPE Vidensbase

Fejlkodeindeks · medium

P1122

APP Sensor sense circuit low voltage – APP1

APP Sensor sense circuit low voltage – APP1

Scope: 2.5L/3.0L gasoline · System(s): EMS OBD II · Factory MIL flag: 2 · Default action: ECM Default: –APP angle default value used –Speed control inhibited –APP adaptions (wear, variance) inhibited

Common causes

  • APP Sensor to ECM sense circuit (APP1): open circuit
  • high resistance APP Sensor sensor supply circuit: open circuit
  • high resistance APP Sensor failure

Quick checks

  • Confirm freeze-frame and conditions when the code set
  • Inspect connectors, grounds, and harness for the circuit named in the code
  • Compare live sensor values vs expected (unplugged/biased sensors are common)

Fejlkodeindeks →