X‑TYPE Baza znanja

Kazalo kodova grešaka · medium

P0152

HO2 Sensor sense circuit high current – bank 2, upstream (2/1) (Universal oxygen sensor: rich con…

HO2 Sensor sense circuit high current – bank 2, upstream (2/1) (Universal oxygen sensor: rich condition at ECM – low current at sensor)

Documented for: 2.0L gasoline; 2.5L/3.0L gasoline · System(s): EMS EOBD, EMS OBD II · Factory MIL flag: 2

Common causes

  • HO2 Sensor 2/1 disconnected HO2 Sensor 2/1 to ECM variable current circuit fault (HO2 Sensor pin 3) ECM to HO2 Sensor 2/1 constant current circuit fault (HO2 Sensor pin 4) HO2 Sensor 2/1 failure

Quick checks

  • Confirm freeze-frame and conditions when the code set
  • Inspect connectors, grounds, and harness for the circuit named in the code
  • Compare live sensor values vs expected (unplugged/biased sensors are common)

Kazalo kodova grešaka →